SPRUJ42E March 2022 – October 2024 AM2631 , AM2631-Q1 , AM2632 , AM2632-Q1 , AM2634 , AM2634-Q1
PRODUCTION DATA
The THREAD Mapping Value register is used to set the thread ID for a particular classifier entry.
Return to Summary Table
Instance Name | Physical Address |
---|---|
CPSW0 | 5283 E13Ch |
31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 |
RESERVED | |||||||
NONE | |||||||
0h | |||||||
23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 |
RESERVED | |||||||
NONE | |||||||
0h | |||||||
15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 |
THREAD_EN | RESERVED | ||||||
R/W | NONE | ||||||
0h | 0h | ||||||
7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
RESERVED | THREADVAL | ||||||
NONE | R/W | ||||||
0h | 0h |
Bit | Field | Type | Reset | Description |
---|---|---|---|---|
31:16 | RESERVED | NONE | 0h | Reserved |
15 | THREAD_EN | R/W | 0h | Thread Enable - When set the switch will use the threadval for the selected classifier match. If clear the the thread ID will be determined by the THREADMAPDEF register settings. |
14:6 | RESERVED | NONE | 0h | Reserved |
5:0 | THREADVAL | R/W | 0h | Thread Value - This field is the thread ID value that is used to map a classifier hit to thread ID for host traffic. |