SPRUJ42E March 2022 – October 2024 AM2631 , AM2631-Q1 , AM2632 , AM2632-Q1 , AM2634 , AM2634-Q1
PRODUCTION DATA
Action Qualifier Control Register For Output B .
Return to Summary Table
Instance Name | Physical Address |
---|---|
EPWM0_G0 | 5000 0084h |
EPWM0_G1 | 5004 0084h |
EPWM0_G2 | 5008 0084h |
EPWM0_G3 | 500C 0084h |
EPWM1_G0 | 5000 1084h |
EPWM1_G1 | 5004 1084h |
EPWM1_G2 | 5008 1084h |
EPWM1_G3 | 500C 1084h |
EPWM2_G0 | 5000 2084h |
EPWM2_G1 | 5004 2084h |
EPWM2_G2 | 5008 2084h |
EPWM2_G3 | 500C 2084h |
EPWM3_G0 | 5000 3084h |
EPWM3_G1 | 5004 3084h |
EPWM3_G2 | 5008 3084h |
EPWM3_G3 | 500C 3084h |
EPWM4_G0 | 5000 4084h |
EPWM4_G1 | 5004 4084h |
EPWM4_G2 | 5008 4084h |
EPWM4_G3 | 500C 4084h |
EPWM5_G0 | 5000 5084h |
EPWM5_G1 | 5004 5084h |
EPWM5_G2 | 5008 5084h |
EPWM5_G3 | 500C 5084h |
EPWM6_G0 | 5000 6084h |
EPWM6_G1 | 5004 6084h |
EPWM6_G2 | 5008 6084h |
EPWM6_G3 | 500C 6084h |
EPWM7_G0 | 5000 7084h |
EPWM7_G1 | 5004 7084h |
EPWM7_G2 | 5008 7084h |
EPWM7_G3 | 500C 7084h |
EPWM8_G0 | 5000 8084h |
EPWM8_G1 | 5004 8084h |
EPWM8_G2 | 5008 8084h |
EPWM8_G3 | 500C 8084h |
EPWM9_G0 | 5000 9084h |
EPWM9_G1 | 5004 9084h |
EPWM9_G2 | 5008 9084h |
EPWM9_G3 | 500C 9084h |
EPWM10_G0 | 5000 A084h |
EPWM10_G1 | 5004 A084h |
EPWM10_G2 | 5008 A084h |
EPWM10_G3 | 500C A084h |
EPWM11_G0 | 5000 B084h |
EPWM11_G1 | 5004 B084h |
EPWM11_G2 | 5008 B084h |
EPWM11_G3 | 500C B084h |
EPWM12_G0 | 5000 C084h |
EPWM12_G1 | 5004 C084h |
EPWM12_G2 | 5008 C084h |
EPWM12_G3 | 500C C084h |
EPWM13_G0 | 5000 D084h |
EPWM13_G1 | 5004 D084h |
EPWM13_G2 | 5008 D084h |
EPWM13_G3 | 500C D084h |
EPWM14_G0 | 5000 E084h |
EPWM14_G1 | 5004 E084h |
EPWM14_G2 | 5008 E084h |
EPWM14_G3 | 500C E084h |
EPWM15_G0 | 5000 F084h |
EPWM15_G1 | 5004 F084h |
EPWM15_G2 | 5008 F084h |
EPWM15_G3 | 500C F084h |
EPWM16_G0 | 5001 0084h |
EPWM16_G1 | 5005 0084h |
EPWM16_G2 | 5009 0084h |
EPWM16_G3 | 500D 0084h |
EPWM17_G0 | 5001 1084h |
EPWM17_G1 | 5005 1084h |
EPWM17_G2 | 5009 1084h |
EPWM17_G3 | 500D 1084h |
EPWM18_G0 | 5001 2084h |
EPWM18_G1 | 5005 2084h |
EPWM18_G2 | 5009 2084h |
EPWM18_G3 | 500D 2084h |
EPWM19_G0 | 5001 3084h |
EPWM19_G1 | 5005 3084h |
EPWM19_G2 | 5009 3084h |
EPWM19_G3 | 500D 3084h |
EPWM20_G0 | 5001 4084h |
EPWM20_G1 | 5005 4084h |
EPWM20_G2 | 5009 4084h |
EPWM20_G3 | 500D 4084h |
EPWM21_G0 | 5001 5084h |
EPWM21_G1 | 5005 5084h |
EPWM21_G2 | 5009 5084h |
EPWM21_G3 | 500D 5084h |
EPWM22_G0 | 5001 6084h |
EPWM22_G1 | 5005 6084h |
EPWM22_G2 | 5009 6084h |
EPWM22_G3 | 500D 6084h |
EPWM23_G0 | 5001 7084h |
EPWM23_G1 | 5005 7084h |
EPWM23_G2 | 5009 7084h |
EPWM23_G3 | 500D 7084h |
EPWM24_G0 | 5001 8084h |
EPWM24_G1 | 5005 8084h |
EPWM24_G2 | 5009 8084h |
EPWM24_G3 | 500D 8084h |
EPWM25_G0 | 5001 9084h |
EPWM25_G1 | 5005 9084h |
EPWM25_G2 | 5009 9084h |
EPWM25_G3 | 500D 9084h |
EPWM26_G0 | 5001 A084h |
EPWM26_G1 | 5005 A084h |
EPWM26_G2 | 5009 A084h |
EPWM26_G3 | 500D A084h |
EPWM27_G0 | 5001 B084h |
EPWM27_G1 | 5005 B084h |
EPWM27_G2 | 5009 B084h |
EPWM27_G3 | 500D B084h |
EPWM28_G0 | 5001 C084h |
EPWM28_G1 | 5005 C084h |
EPWM28_G2 | 5009 C084h |
EPWM28_G3 | 500D C084h |
EPWM29_G0 | 5001 D084h |
EPWM29_G1 | 5005 D084h |
EPWM29_G2 | 5009 D084h |
EPWM29_G3 | 500D D084h |
EPWM30_G0 | 5001 E084h |
EPWM30_G1 | 5005 E084h |
EPWM30_G2 | 5009 E084h |
EPWM30_G3 | 500D E084h |
EPWM31_G0 | 5001 F084h |
EPWM31_G1 | 5005 F084h |
EPWM31_G2 | 5009 F084h |
EPWM31_G3 | 500D F084h |
15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 |
RESERVED_1 | CBD | CBU | |||||
R | R/W | R/W | |||||
0h | 0h | 0h | |||||
7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
CAD | CAU | PRD | ZRO | ||||
R/W | R/W | R/W | R/W | ||||
0h | 0h | 0h | 0h |
Bit | Field | Type | Reset | Description |
---|---|---|---|---|
15:12 | RESERVED_1 | R | 0h | Reserved |
11:10 | CBD | R/W | 0h | Action When TBCTR = CMPB on Down Count Note: By definition, in count up-down mode when the counter equals 0 the direction is defined as 1 or counting up. 00:Do nothing [action disabled] 01:Clear: force EPWMxB output low. 10:Set: force EPWMxB output high. 11:Toggle EPWMxB output: low output signal will be forced high, and a high signal will be forced low. |
9:8 | CBU | R/W | 0h | Action When TBCTR = CMPB on Up Count Note: By definition, in count up-down mode when the counter equals 0 the direction is defined as 1 or counting up. 00:Do nothing [action disabled] 01:Clear: force EPWMxB output low. 10:Set: force EPWMxB output high. 11:Toggle EPWMxB output: low output signal will be forced high, and a high signal will be forced low. |
7:6 | CAD | R/W | 0h | Action When TBCTR = CMPA on Down Count Note: By definition, in count up-down mode when the counter equals 0 the direction is defined as 1 or counting up. 00:Do nothing [action disabled] 01:Clear: force EPWMxB output low. 10:Set: force EPWMxB output high. 11:Toggle EPWMxB output: low output signal will be forced high, and a high signal will be forced low. |
5:4 | CAU | R/W | 0h | Action When TBCTR = CMPA on Up Count Note: By definition, in count up-down mode when the counter equals 0 the direction is defined as 1 or counting up. 00:Do nothing [action disabled] 01:Clear: force EPWMxB output low. 10:Set: force EPWMxB output high. 11:Toggle EPWMxB output: low output signal will be forced high, and a high signal will be forced low. |
3:2 | PRD | R/W | 0h | Action When TBCTR = TBPRD Note: By definition, in count up-down mode when the counter equals 0 the direction is defined as 1 or counting up. 00:Do nothing [action disabled] 01:Clear: force EPWMxB output low. 10:Set: force EPWMxB output high. 11:Toggle EPWMxB output: low output signal will be forced high, and a high signal will be forced low. |
1:0 | ZRO | R/W | 0h | Action When TBCTR = 0 Note: By definition, in count up-down mode when the counter equals 0 the direction is defined as 1 or counting up. 00:Do nothing [action disabled] 01:Clear: force EPWMxB output low. 10:Set: force EPWMxB output high. 11:Toggle EPWMxB output: low output signal will be forced high, and a high signal will be forced low. |