SPRUJ42E March 2022 – October 2024 AM2631 , AM2631-Q1 , AM2632 , AM2632-Q1 , AM2634 , AM2634-Q1
PRODUCTION DATA
Digital Compare Filter Window Register.
Return to Summary Table
Instance Name | Physical Address |
---|---|
EPWM0_G0 | 5000 0196h |
EPWM0_G1 | 5004 0196h |
EPWM0_G2 | 5008 0196h |
EPWM0_G3 | 500C 0196h |
EPWM1_G0 | 5000 1196h |
EPWM1_G1 | 5004 1196h |
EPWM1_G2 | 5008 1196h |
EPWM1_G3 | 500C 1196h |
EPWM2_G0 | 5000 2196h |
EPWM2_G1 | 5004 2196h |
EPWM2_G2 | 5008 2196h |
EPWM2_G3 | 500C 2196h |
EPWM3_G0 | 5000 3196h |
EPWM3_G1 | 5004 3196h |
EPWM3_G2 | 5008 3196h |
EPWM3_G3 | 500C 3196h |
EPWM4_G0 | 5000 4196h |
EPWM4_G1 | 5004 4196h |
EPWM4_G2 | 5008 4196h |
EPWM4_G3 | 500C 4196h |
EPWM5_G0 | 5000 5196h |
EPWM5_G1 | 5004 5196h |
EPWM5_G2 | 5008 5196h |
EPWM5_G3 | 500C 5196h |
EPWM6_G0 | 5000 6196h |
EPWM6_G1 | 5004 6196h |
EPWM6_G2 | 5008 6196h |
EPWM6_G3 | 500C 6196h |
EPWM7_G0 | 5000 7196h |
EPWM7_G1 | 5004 7196h |
EPWM7_G2 | 5008 7196h |
EPWM7_G3 | 500C 7196h |
EPWM8_G0 | 5000 8196h |
EPWM8_G1 | 5004 8196h |
EPWM8_G2 | 5008 8196h |
EPWM8_G3 | 500C 8196h |
EPWM9_G0 | 5000 9196h |
EPWM9_G1 | 5004 9196h |
EPWM9_G2 | 5008 9196h |
EPWM9_G3 | 500C 9196h |
EPWM10_G0 | 5000 A196h |
EPWM10_G1 | 5004 A196h |
EPWM10_G2 | 5008 A196h |
EPWM10_G3 | 500C A196h |
EPWM11_G0 | 5000 B196h |
EPWM11_G1 | 5004 B196h |
EPWM11_G2 | 5008 B196h |
EPWM11_G3 | 500C B196h |
EPWM12_G0 | 5000 C196h |
EPWM12_G1 | 5004 C196h |
EPWM12_G2 | 5008 C196h |
EPWM12_G3 | 500C C196h |
EPWM13_G0 | 5000 D196h |
EPWM13_G1 | 5004 D196h |
EPWM13_G2 | 5008 D196h |
EPWM13_G3 | 500C D196h |
EPWM14_G0 | 5000 E196h |
EPWM14_G1 | 5004 E196h |
EPWM14_G2 | 5008 E196h |
EPWM14_G3 | 500C E196h |
EPWM15_G0 | 5000 F196h |
EPWM15_G1 | 5004 F196h |
EPWM15_G2 | 5008 F196h |
EPWM15_G3 | 500C F196h |
EPWM16_G0 | 5001 0196h |
EPWM16_G1 | 5005 0196h |
EPWM16_G2 | 5009 0196h |
EPWM16_G3 | 500D 0196h |
EPWM17_G0 | 5001 1196h |
EPWM17_G1 | 5005 1196h |
EPWM17_G2 | 5009 1196h |
EPWM17_G3 | 500D 1196h |
EPWM18_G0 | 5001 2196h |
EPWM18_G1 | 5005 2196h |
EPWM18_G2 | 5009 2196h |
EPWM18_G3 | 500D 2196h |
EPWM19_G0 | 5001 3196h |
EPWM19_G1 | 5005 3196h |
EPWM19_G2 | 5009 3196h |
EPWM19_G3 | 500D 3196h |
EPWM20_G0 | 5001 4196h |
EPWM20_G1 | 5005 4196h |
EPWM20_G2 | 5009 4196h |
EPWM20_G3 | 500D 4196h |
EPWM21_G0 | 5001 5196h |
EPWM21_G1 | 5005 5196h |
EPWM21_G2 | 5009 5196h |
EPWM21_G3 | 500D 5196h |
EPWM22_G0 | 5001 6196h |
EPWM22_G1 | 5005 6196h |
EPWM22_G2 | 5009 6196h |
EPWM22_G3 | 500D 6196h |
EPWM23_G0 | 5001 7196h |
EPWM23_G1 | 5005 7196h |
EPWM23_G2 | 5009 7196h |
EPWM23_G3 | 500D 7196h |
EPWM24_G0 | 5001 8196h |
EPWM24_G1 | 5005 8196h |
EPWM24_G2 | 5009 8196h |
EPWM24_G3 | 500D 8196h |
EPWM25_G0 | 5001 9196h |
EPWM25_G1 | 5005 9196h |
EPWM25_G2 | 5009 9196h |
EPWM25_G3 | 500D 9196h |
EPWM26_G0 | 5001 A196h |
EPWM26_G1 | 5005 A196h |
EPWM26_G2 | 5009 A196h |
EPWM26_G3 | 500D A196h |
EPWM27_G0 | 5001 B196h |
EPWM27_G1 | 5005 B196h |
EPWM27_G2 | 5009 B196h |
EPWM27_G3 | 500D B196h |
EPWM28_G0 | 5001 C196h |
EPWM28_G1 | 5005 C196h |
EPWM28_G2 | 5009 C196h |
EPWM28_G3 | 500D C196h |
EPWM29_G0 | 5001 D196h |
EPWM29_G1 | 5005 D196h |
EPWM29_G2 | 5009 D196h |
EPWM29_G3 | 500D D196h |
EPWM30_G0 | 5001 E196h |
EPWM30_G1 | 5005 E196h |
EPWM30_G2 | 5009 E196h |
EPWM30_G3 | 500D E196h |
EPWM31_G0 | 5001 F196h |
EPWM31_G1 | 5005 F196h |
EPWM31_G2 | 5009 F196h |
EPWM31_G3 | 500D F196h |
15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 |
DCFWINDOW | |||||||
R/W | |||||||
0h | |||||||
7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
DCFWINDOW | |||||||
R/W | |||||||
0h |
Bit | Field | Type | Reset | Description |
---|---|---|---|---|
15:0 | DCFWINDOW | R/W | 0h | Blanking Window Width 00h No blanking window is generated. 01-FFFFh: Specifies the width of the blanking window in TBCLK cycles. The blanking window begins when the offset counter expires. When this occurs, the window counter is loaded and begins to count down. If the blanking window is currently active and the offset counter expires, the blanking window counter is not restarted and the blanking window is cut short prematurely. Care should be taken to avoid this situation. The blanking window can cross a PWM period boundary. |