SPRUJ42E March 2022 – October 2024 AM2631 , AM2631-Q1 , AM2632 , AM2632-Q1 , AM2634 , AM2634-Q1
PRODUCTION DATA
Additional Time Base Period Active Register.
Return to Summary Table
Instance Name | Physical Address |
---|---|
EPWM0_G0 | 5000 0620h |
EPWM0_G1 | 5004 0620h |
EPWM0_G2 | 5008 0620h |
EPWM0_G3 | 500C 0620h |
EPWM1_G0 | 5000 1620h |
EPWM1_G1 | 5004 1620h |
EPWM1_G2 | 5008 1620h |
EPWM1_G3 | 500C 1620h |
EPWM2_G0 | 5000 2620h |
EPWM2_G1 | 5004 2620h |
EPWM2_G2 | 5008 2620h |
EPWM2_G3 | 500C 2620h |
EPWM3_G0 | 5000 3620h |
EPWM3_G1 | 5004 3620h |
EPWM3_G2 | 5008 3620h |
EPWM3_G3 | 500C 3620h |
EPWM4_G0 | 5000 4620h |
EPWM4_G1 | 5004 4620h |
EPWM4_G2 | 5008 4620h |
EPWM4_G3 | 500C 4620h |
EPWM5_G0 | 5000 5620h |
EPWM5_G1 | 5004 5620h |
EPWM5_G2 | 5008 5620h |
EPWM5_G3 | 500C 5620h |
EPWM6_G0 | 5000 6620h |
EPWM6_G1 | 5004 6620h |
EPWM6_G2 | 5008 6620h |
EPWM6_G3 | 500C 6620h |
EPWM7_G0 | 5000 7620h |
EPWM7_G1 | 5004 7620h |
EPWM7_G2 | 5008 7620h |
EPWM7_G3 | 500C 7620h |
EPWM8_G0 | 5000 8620h |
EPWM8_G1 | 5004 8620h |
EPWM8_G2 | 5008 8620h |
EPWM8_G3 | 500C 8620h |
EPWM9_G0 | 5000 9620h |
EPWM9_G1 | 5004 9620h |
EPWM9_G2 | 5008 9620h |
EPWM9_G3 | 500C 9620h |
EPWM10_G0 | 5000 A620h |
EPWM10_G1 | 5004 A620h |
EPWM10_G2 | 5008 A620h |
EPWM10_G3 | 500C A620h |
EPWM11_G0 | 5000 B620h |
EPWM11_G1 | 5004 B620h |
EPWM11_G2 | 5008 B620h |
EPWM11_G3 | 500C B620h |
EPWM12_G0 | 5000 C620h |
EPWM12_G1 | 5004 C620h |
EPWM12_G2 | 5008 C620h |
EPWM12_G3 | 500C C620h |
EPWM13_G0 | 5000 D620h |
EPWM13_G1 | 5004 D620h |
EPWM13_G2 | 5008 D620h |
EPWM13_G3 | 500C D620h |
EPWM14_G0 | 5000 E620h |
EPWM14_G1 | 5004 E620h |
EPWM14_G2 | 5008 E620h |
EPWM14_G3 | 500C E620h |
EPWM15_G0 | 5000 F620h |
EPWM15_G1 | 5004 F620h |
EPWM15_G2 | 5008 F620h |
EPWM15_G3 | 500C F620h |
EPWM16_G0 | 5001 0620h |
EPWM16_G1 | 5005 0620h |
EPWM16_G2 | 5009 0620h |
EPWM16_G3 | 500D 0620h |
EPWM17_G0 | 5001 1620h |
EPWM17_G1 | 5005 1620h |
EPWM17_G2 | 5009 1620h |
EPWM17_G3 | 500D 1620h |
EPWM18_G0 | 5001 2620h |
EPWM18_G1 | 5005 2620h |
EPWM18_G2 | 5009 2620h |
EPWM18_G3 | 500D 2620h |
EPWM19_G0 | 5001 3620h |
EPWM19_G1 | 5005 3620h |
EPWM19_G2 | 5009 3620h |
EPWM19_G3 | 500D 3620h |
EPWM20_G0 | 5001 4620h |
EPWM20_G1 | 5005 4620h |
EPWM20_G2 | 5009 4620h |
EPWM20_G3 | 500D 4620h |
EPWM21_G0 | 5001 5620h |
EPWM21_G1 | 5005 5620h |
EPWM21_G2 | 5009 5620h |
EPWM21_G3 | 500D 5620h |
EPWM22_G0 | 5001 6620h |
EPWM22_G1 | 5005 6620h |
EPWM22_G2 | 5009 6620h |
EPWM22_G3 | 500D 6620h |
EPWM23_G0 | 5001 7620h |
EPWM23_G1 | 5005 7620h |
EPWM23_G2 | 5009 7620h |
EPWM23_G3 | 500D 7620h |
EPWM24_G0 | 5001 8620h |
EPWM24_G1 | 5005 8620h |
EPWM24_G2 | 5009 8620h |
EPWM24_G3 | 500D 8620h |
EPWM25_G0 | 5001 9620h |
EPWM25_G1 | 5005 9620h |
EPWM25_G2 | 5009 9620h |
EPWM25_G3 | 500D 9620h |
EPWM26_G0 | 5001 A620h |
EPWM26_G1 | 5005 A620h |
EPWM26_G2 | 5009 A620h |
EPWM26_G3 | 500D A620h |
EPWM27_G0 | 5001 B620h |
EPWM27_G1 | 5005 B620h |
EPWM27_G2 | 5009 B620h |
EPWM27_G3 | 500D B620h |
EPWM28_G0 | 5001 C620h |
EPWM28_G1 | 5005 C620h |
EPWM28_G2 | 5009 C620h |
EPWM28_G3 | 500D C620h |
EPWM29_G0 | 5001 D620h |
EPWM29_G1 | 5005 D620h |
EPWM29_G2 | 5009 D620h |
EPWM29_G3 | 500D D620h |
EPWM30_G0 | 5001 E620h |
EPWM30_G1 | 5005 E620h |
EPWM30_G2 | 5009 E620h |
EPWM30_G3 | 500D E620h |
EPWM31_G0 | 5001 F620h |
EPWM31_G1 | 5005 F620h |
EPWM31_G2 | 5009 F620h |
EPWM31_G3 | 500D F620h |
31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 |
XTBPRD_ACTIVE | |||||||
R/W | |||||||
0h | |||||||
23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 |
XTBPRD_ACTIVE | |||||||
R/W | |||||||
0h | |||||||
15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 |
XTBPRDHR_ACTIVE | |||||||
R/W | |||||||
0h | |||||||
7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
XTBPRDHR_ACTIVE | |||||||
R/W | |||||||
0h |
Bit | Field | Type | Reset | Description |
---|---|---|---|---|
31:16 | XTBPRD_ACTIVE | R/W | 0h | The value in the XTBPRD_ACTIVE register is loaded into TBPRD [shadow/active] registers when shadow to active load occurs. |
15:0 | XTBPRDHR_ACTIVE | R/W | 0h | The value in the XTBPRDHR_ACTIVE register is loaded into TBPRDHR [shadow/active] registers when shadow to active load occurs. |