SPRUJ42E March 2022 – October 2024 AM2631 , AM2631-Q1 , AM2632 , AM2632-Q1 , AM2634 , AM2634-Q1
PRODUCTION DATA
Additional Compare 2 Shadow 1 Register.
Return to Summary Table
Instance Name | Physical Address |
---|---|
EPWM0_G0 | 5000 0684h |
EPWM0_G1 | 5004 0684h |
EPWM0_G2 | 5008 0684h |
EPWM0_G3 | 500C 0684h |
EPWM1_G0 | 5000 1684h |
EPWM1_G1 | 5004 1684h |
EPWM1_G2 | 5008 1684h |
EPWM1_G3 | 500C 1684h |
EPWM2_G0 | 5000 2684h |
EPWM2_G1 | 5004 2684h |
EPWM2_G2 | 5008 2684h |
EPWM2_G3 | 500C 2684h |
EPWM3_G0 | 5000 3684h |
EPWM3_G1 | 5004 3684h |
EPWM3_G2 | 5008 3684h |
EPWM3_G3 | 500C 3684h |
EPWM4_G0 | 5000 4684h |
EPWM4_G1 | 5004 4684h |
EPWM4_G2 | 5008 4684h |
EPWM4_G3 | 500C 4684h |
EPWM5_G0 | 5000 5684h |
EPWM5_G1 | 5004 5684h |
EPWM5_G2 | 5008 5684h |
EPWM5_G3 | 500C 5684h |
EPWM6_G0 | 5000 6684h |
EPWM6_G1 | 5004 6684h |
EPWM6_G2 | 5008 6684h |
EPWM6_G3 | 500C 6684h |
EPWM7_G0 | 5000 7684h |
EPWM7_G1 | 5004 7684h |
EPWM7_G2 | 5008 7684h |
EPWM7_G3 | 500C 7684h |
EPWM8_G0 | 5000 8684h |
EPWM8_G1 | 5004 8684h |
EPWM8_G2 | 5008 8684h |
EPWM8_G3 | 500C 8684h |
EPWM9_G0 | 5000 9684h |
EPWM9_G1 | 5004 9684h |
EPWM9_G2 | 5008 9684h |
EPWM9_G3 | 500C 9684h |
EPWM10_G0 | 5000 A684h |
EPWM10_G1 | 5004 A684h |
EPWM10_G2 | 5008 A684h |
EPWM10_G3 | 500C A684h |
EPWM11_G0 | 5000 B684h |
EPWM11_G1 | 5004 B684h |
EPWM11_G2 | 5008 B684h |
EPWM11_G3 | 500C B684h |
EPWM12_G0 | 5000 C684h |
EPWM12_G1 | 5004 C684h |
EPWM12_G2 | 5008 C684h |
EPWM12_G3 | 500C C684h |
EPWM13_G0 | 5000 D684h |
EPWM13_G1 | 5004 D684h |
EPWM13_G2 | 5008 D684h |
EPWM13_G3 | 500C D684h |
EPWM14_G0 | 5000 E684h |
EPWM14_G1 | 5004 E684h |
EPWM14_G2 | 5008 E684h |
EPWM14_G3 | 500C E684h |
EPWM15_G0 | 5000 F684h |
EPWM15_G1 | 5004 F684h |
EPWM15_G2 | 5008 F684h |
EPWM15_G3 | 500C F684h |
EPWM16_G0 | 5001 0684h |
EPWM16_G1 | 5005 0684h |
EPWM16_G2 | 5009 0684h |
EPWM16_G3 | 500D 0684h |
EPWM17_G0 | 5001 1684h |
EPWM17_G1 | 5005 1684h |
EPWM17_G2 | 5009 1684h |
EPWM17_G3 | 500D 1684h |
EPWM18_G0 | 5001 2684h |
EPWM18_G1 | 5005 2684h |
EPWM18_G2 | 5009 2684h |
EPWM18_G3 | 500D 2684h |
EPWM19_G0 | 5001 3684h |
EPWM19_G1 | 5005 3684h |
EPWM19_G2 | 5009 3684h |
EPWM19_G3 | 500D 3684h |
EPWM20_G0 | 5001 4684h |
EPWM20_G1 | 5005 4684h |
EPWM20_G2 | 5009 4684h |
EPWM20_G3 | 500D 4684h |
EPWM21_G0 | 5001 5684h |
EPWM21_G1 | 5005 5684h |
EPWM21_G2 | 5009 5684h |
EPWM21_G3 | 500D 5684h |
EPWM22_G0 | 5001 6684h |
EPWM22_G1 | 5005 6684h |
EPWM22_G2 | 5009 6684h |
EPWM22_G3 | 500D 6684h |
EPWM23_G0 | 5001 7684h |
EPWM23_G1 | 5005 7684h |
EPWM23_G2 | 5009 7684h |
EPWM23_G3 | 500D 7684h |
EPWM24_G0 | 5001 8684h |
EPWM24_G1 | 5005 8684h |
EPWM24_G2 | 5009 8684h |
EPWM24_G3 | 500D 8684h |
EPWM25_G0 | 5001 9684h |
EPWM25_G1 | 5005 9684h |
EPWM25_G2 | 5009 9684h |
EPWM25_G3 | 500D 9684h |
EPWM26_G0 | 5001 A684h |
EPWM26_G1 | 5005 A684h |
EPWM26_G2 | 5009 A684h |
EPWM26_G3 | 500D A684h |
EPWM27_G0 | 5001 B684h |
EPWM27_G1 | 5005 B684h |
EPWM27_G2 | 5009 B684h |
EPWM27_G3 | 500D B684h |
EPWM28_G0 | 5001 C684h |
EPWM28_G1 | 5005 C684h |
EPWM28_G2 | 5009 C684h |
EPWM28_G3 | 500D C684h |
EPWM29_G0 | 5001 D684h |
EPWM29_G1 | 5005 D684h |
EPWM29_G2 | 5009 D684h |
EPWM29_G3 | 500D D684h |
EPWM30_G0 | 5001 E684h |
EPWM30_G1 | 5005 E684h |
EPWM30_G2 | 5009 E684h |
EPWM30_G3 | 500D E684h |
EPWM31_G0 | 5001 F684h |
EPWM31_G1 | 5005 F684h |
EPWM31_G2 | 5009 F684h |
EPWM31_G3 | 500D F684h |
31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 |
XCMP2_SHDW1 | |||||||
R/W | |||||||
0h | |||||||
23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 |
XCMP2_SHDW1 | |||||||
R/W | |||||||
0h | |||||||
15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 |
XCMP2HR_SHDW1 | |||||||
R/W | |||||||
0h | |||||||
7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
XCMP2HR_SHDW1 | |||||||
R/W | |||||||
0h |
Bit | Field | Type | Reset | Description |
---|---|---|---|---|
31:16 | XCMP2_SHDW1 | R/W | 0h | XCMP2_SHDW1 Register The value in the XCMP2_SHDW1 register is loaded into XCMP2_ACTIVE register when shadow to active load occurs. |
15:0 | XCMP2HR_SHDW1 | R/W | 0h | XCMP2HR_SHDW1 Register The value in the XCMP2HR_SHDW1 register is loaded into XCMP2HR_ACTIVE register when shadow to active load occurs. |