SPRUJ53B April 2024 – September 2024 TMS320F28P550SJ , TMS320F28P559SJ-Q1
The ADC's post-processing block has the capability to calculate the delta from the previous conversion sample. When enabled, the ADCPPBxRESULT register contains the difference between the current conversion result and the previous conversion. This delta is computed on the actual conversion result, not the result of the a prior delta calculation. The delta calculation occurs after OFFREF, TWOSCOMPEN and ABSEN calculations have been applied.
To enable result delta computation, write 1 to the DELTAEN bit in the ADCPPBxCONFIG register.