SPRZ193T January 2003 – December 2023 SM320F2812 , SM320F2812-EP , SMJ320F2812 , TMS320F2810 , TMS320F2810-Q1 , TMS320F2811 , TMS320F2811-Q1 , TMS320F2812 , TMS320F2812-Q1
Memory: Program Reads From Flash/ROM Memory
0, A, B, C, D, E, F and G
When an interrupt occurs while program code is executing instructions from the address range 0x3F7FF0 through 0x3F7FF7, it is possible that subsequent data reads from the Flash/ROM will return all zeros.
Do not place program code within this address range. This range can be used for data variable storage.