When this display tab is selected, the
screen shows the following information (see Figure 3-10).
- Platform: the hexadecimal string that is output by the mmWave
sensor device.
- SDK version: the version of the software that is currently
running on the mmWave sensor device.
- Number of Detected Objects: a continuously updating field (new
measurement every frame) that shows the number of detected objects for a given
frame.
- Frame Stats or Stats for Subframe: In the case of advanced
frame configuration, this lists the subframes (separated by command) for which
the following stats are displayed. In the case of legacy frame configuration,
there is only one construct of the frame and the following stats apply for the
whole frame.
- InterChirpProcessingMargin: a continuously updating
field (new measurement every frame) that shows the time, in
microseconds, that is left in a given (chirp + interchirp) duration
after the chirp processing. The field has the value that is the average
value across all chirps in a given frame, or values separated by commas
which are the average value across all chirps in a given subframe.
- InterFrameProcessingMargin: a continuously updating
field (new measurement every frame) that shows the time, in
microseconds, that is left in a given frame/subframe after all the
frame/subframe processing is completed.
- InterFrameProcessingTime: a continuously updating
field (new measurement every frame) that shows the time, in
microseconds, that was consumed for frame/subframe processing after the
active chirps were completed.
- TransmitOutputTime: a continuously updating field (new
measurement every frame) that shows the time, in microseconds, for the
requested output (controlled using the selections in the Plot Selection
section of the Configure tab) to be shipped out over the UART from the
mmWave device to the PC.
- Active/Interframe CPU Load (%): a continuously
updating field (new measurement every frame) that shows the percentage
CPU load during active chirping time within the frame/subframe and the
interframe/intersubframe time. These values are also reflected on the
CPU Load plot for the frame, or the first selected subframe in the
guiMonitor command.
- Temperature Report: This section displays the device temperature report from
various temperature sensors. The time shown is number of
days/hours/minutes/seconds/milliseconds since the device was powered up.