SWRZ062F September 2015 – December 2022 CC1310
Synthesizer Calibration Might Fail on Rare Occasions
A and B
The synthesizer calibration has been observed to fail on rare occasions. This will cause any radio command that requires a calibrated synthesizer to fail.
SIMPLELINK-CC13X0-SDK_2.20.00.38 and later includes an improved synthesizer start-up sequence that reduces the probability of synthesizer calibration failure.
The workaround for a failed synthesizer calibration is to calibrate again.
TI provided software stacks
For applications that use the software stacks delivered by TI, no action is required because error handling is implemented by the stacks.
Other (customer developed) software stacks
For applications that use TI-RTOS or CC13XXWARE together with customer-developed software stacks, TI recommends that proper run-time error handling is performed when executing a radio command. See the software documentation included in TI-RTOS for Microcontrollers (MCU) documentation for error codes.