SWRZ099B April 2020 – March 2022 AWR6843AOP
Overshoot and Undershoot During Inter-Chirp Idle Time
AWR6843AOP ES2.0
At the end of the chirp , when the synthesizer starts to go back to the start frequency of the next chirp, there is some overshoot and undershoot. The undershoot/overshoot is proportional to the chirp bandwidth. Negative slope chirps have a worse undershoot than positive slope chirps.
To ensure the TX power amplifier is OFF during chirp idle time and not causing "on-air" emissions during the undershoot/overshoot period, keep the inter-chirp power savings ON.