TIDT302 August   2022

 

  1.   Description
  2.   Features
  3.   Applications
  4. 1Test Prerequisites
    1. 1.1 Voltage and Current Requirements
    2. 1.2 Required Equipment
    3. 1.3 Considerations
    4. 1.4 Dimensions
    5. 1.5 Test Setup
  5. 2Testing and Results
    1. 2.1 Load Regulation Graph
    2. 2.2 Efficiency Graphs
    3. 2.3 Efficiency Data
    4. 2.4 Thermal Images
  6. 3Waveforms
    1. 3.1 Switching
    2. 3.2 Output Voltage Ripple
    3. 3.3 Load Transients
    4. 3.4 Start-up Sequence

Efficiency Data

Efficiency data is shown in the following table.

Table 2-1 Efficiency Data
Input Voltage SettingInput Current

(mA)

VOUT1 Voltage (V)VOUT1 Current (mA)VOUT2 Voltage (V)VOUT2

Current (mA)

Total Input Power (W)Total Output Power (W)Efficiency

(%)

Power

Loss (W)

12 VDC183.318.6423.7918.720.0752.19960.444820.221.7548
196.518.4942.9318.650.0752.35800.795233.721.5628
213.318.3762.1618.620.0752.55961.143344.671.4163
23118.6186.5518.180.082.77201.612158.161.1599
17818.750.01618.6718.472.13600.344016.111.7920
191.118.690.01718.5338.72.29320.717431.291.5758
20218.660.01518.458.82.4241.082244.651.3418
233.418.640.01518.2583.842.80081.530454.641.2704
210.518.5723.5418.623.242.52600.869434.421.6566
23218.4142.6818.4238.52.78401.494953.701.2891
252.318.2561.918.2558.683.02762.20172.680.8270
321.817.8986.317.9383.683.86163.044378.830.8173