TIDT409 September   2024

 

  1.   1
  2.   Description
  3.   Features
  4.   Applications
  5. 1Test Prerequisites
    1. 1.1 Voltage and Current Requirements
    2. 1.2 Required Equipment
    3. 1.3 Dimensions
  6. 2Testing and Results
    1. 2.1 Efficiency Graphs
    2. 2.2 Efficiency Data
    3. 2.3 Thermal Images
    4. 2.4 Bode Plots
    5. 2.5 EMI
  7. 3Waveforms
    1. 3.1 Switching
    2. 3.2 Output Voltage Ripple

Voltage and Current Requirements

Table 1-1 Voltage and Current Requirements
PARAMETERSPECIFICATIONS
Input Voltage14VDC
PA_BUS Output Voltage5VDC, 9VDC, 15VDC, 20VDC

PA_BUS Maximum Output Current

3A
PA_BUS Maximum Output Power45W
PB_BUS Output Voltage5VDC, 9VDC, 15VDC, 20VDC
PB_BUS Maximum Output Current3A
PB_BUS Maximum Output Power45W
Switching Frequency400kHz