TIDUEO0C July 2019 – March 2021
Both TIDA-010053 and TIDA-01546 designs can be combined to enable both periodic SOH measurements and the continuous System Health Monitoring. The updated TIDA-01546 software is programmed into the T4MC MCU, as explained in the Reprogram TIDA-01546 section of the Battery and System Health Monitoring of Battery-Powered Smart Flow Meters Reference Design Guide.
This software supports logging data onto a microSD card and a UART communication port is added to the source code of the TM4C host MCU. Thus, sending out log data to a COM port of a PC, running a terminal program such as HTerm, is possible.
The software for the TIDA-01546 design is updated to the latest Tiva_C MCU library, named TivaWare_C_Series-2.1.4.178 as well as CCS version 9.0.1 (latest as of June 2019).