This reference design uses multiple voltage domains across the system:
- A primary bias power input to power the entire
design (regulated 12 V). This is used to directly power relays and fans used on
the board. There is a connector provision on the main board to generate this
12-V supply directly from the high-voltage DC bus.
- A TPS563200 synchronous buck converter generates
5 V to power the control card and power cards from the 12 V main power. Each of
the power cards generate its own isolated power supply for gate driving from
this 5-V power supply.
- The 3.3-V supply for analog sensing and logic is
generated by an LDO LP5907 from the 5 V.
Figure 2-12
shows the power tree for all of these domains.