DLPS133B June 2019 – July 2024 TPS99001-Q1
PRODUCTION DATA
ADDRESS | NAME | BITS | DESCRIPTION |
---|---|---|---|
ADC Block Status SET, Read, Reset Value 0000 | |||
0x0D | Unused | [15:8] | Reserved |
AD3 Command Stop-bit Error | [7] | Indicates that a stop bit was missing | |
ADC Timeline Error | [6] | Indicates that a new command was received while previous command was still in progress | |
Command error | [5] | An error was detected on a serial bus command | |
Parity error detected | [4] | A parity error in bit stream was detected | |
Ch2 underflow | [3] | ADC conversion results presented in channel two register experienced an underflow | |
Ch2 saturated | [2] | ADC conversion results presented in channel two register are saturated | |
Ch1 underflow | [1] | ADC conversion results presented in channel one register experienced an underflow | |
Ch1 saturated | [0] | ADC conversion results presented in channel one register are saturated |