DLPU041G April 2016 – July 2024 DLPC230-Q1 , DLPC230S-Q1
This command is used to clear the Error History, the Error Count, and the Short Status error bits.
Write Parameters
BYTE | BITS | DESCRIPTION |
---|---|---|
1 | 7:0 | Signature Byte 1 0xAA |
2 | 7:0 | Signature Byte 2 0xBB |
3 | 7:0 | Signature Byte 3 0xCC |
4 | 7:0 | Signature Byte 4 0xDD |