DLPU048E August 2016 – July 2024
This command is used to read back the host-specified values for the average picture level function. It also returns the most recent average picture level value from the function.
Command Parameters
No command parameters.
Return Parameters
BYTE | BITS | DESCRIPTION |
---|---|---|
1 | 7:0 | APL Control 0x0: Disable 0x1: Enable - Log error if threshold is exceeded 0x2: Enable - Log error and execute emergency shutdown if threshold is exceeded |
2 | 7:0 | APL Threshold Host-specified threshold picture level. |
3 | 7:0 | APL Value Most recent average picture level value. |