DLPU057A March 2018 – April 2022 DLP3030-Q1
This is the data response for a request to read the Low Pass Filter Constants.
Byte | Description |
1 | Response Byte (01h) |
2 | Length (08h) |
3 | Low Pass Filter Strength (lsb) |
4 | Low Pass Filter Strength |
5 | Low Pass Filter Strength |
6 | Low Pass Filter Strength (msb) |
7 | Low Pass Filter Quantization Step (lsb) |
8 | Low Pass Filter Quantization Step |
9 | Low Pass Filter Quantization Step |
10 | Low Pass Filter Quantization Step (msb) |
11 | Checksum (Sum of bytes 1 to 10) |
Note: The Filter Coefficients are floating point numbers. Please refer to Section 5 for the read and write format for such numbers.