This is the data response for a request to read the power rail voltages.
Byte | Description |
1 | Response Byte (01h) |
2 | Length (11h) |
3 | 1.2-V Rail Voltage (lsb) |
4 | 1.2-V Rail Voltage |
5 | 1.2-V Rail Voltage |
6 | 1.2-V Rail Voltage (msb) |
7 | 1.8-V Rail Voltage (lsb) |
8 | 1.8-V Rail Voltage |
9 | 1.8-V Rail Voltage |
10 | 1.8-V Rail Voltage (msb) |
11 | 2.5-V Rail Voltage (lsb) |
12 | 2.5-V Rail Voltage |
13 | 2.5-V Rail Voltage |
14 | 2.5-V Rail Voltage (msb) |
15 | 3.3-V Rail Voltage (lsb) |
16 | 3.3-V Rail Voltage |
17 | 3.3-V Rail Voltage |
18 | 3.3-V Rail Voltage (msb) |
19 | System Reset state |
20 | Checksum (sum of bytes 1 to 19) |
Note: The Power Rail Voltages are floating point numbers. Please refer to Section 5.3 for the read format for such numbers.
System state ‘0’ indicates normal operation and ‘1’ indicates reset state.