DLPU057A March 2018 – April 2022
This is the data response for a valid request to read the PWM Scale Factor.
Byte | Description |
1 | Response Byte (01h) |
2 | Length (06h) |
3 | Current PWM MEP Scale Factor (lsb) |
4 | Current PWM MEP Scale Factor (msb) |
5 | Minimum PWM MEP Scale Factor (lsb) |
6 | Minimum PWM MEP Scale Factor (msb)) |
7 | Maximum PWM MEP Scale Factor (lsb) |
8 | Maximum PWM MEP Scale Factor (msb) |
9 | Checksum (Sum of bytes 1 to 8) |