SBAA449B October 2020 – October 2021 TMAG5110 , TMAG5110-Q1 , TMAG5111 , TMAG5111-Q1
An additional alternative to reduce error is to increase the magnet strength. With amplitude mismatch, we can expect the greatest errors to arise when the BOP & BRP thresholds are close to the peak input value. Moreover, the zero crossings always remain electrically out of phase by 90°. Therefore, the closer the BRP & BOP thresholds are relative to the zero crossing value, the better the quadrature result.
See Table 4-1 extracted from the material variation simulation. To find angle error we will find where the z-component of the magnetic field reaches 1.1 mT and the θ component reaches 2.6 mT. This is to ensure we capture the maximum sensitivity error possible.
Material | BOP - Z | BOP - θ | Angle Error |
---|---|---|---|
Bonded Ceramic | 0.57° | 29.4° | 1.83° |
SmCo 18 | 0.15° | 27.68° | 0.53° |
N35 | 0.12° | 27.49° | 0.37° |