SBAS790C October 2018 – June 2019 ADS125H02
PRODUCTION DATA.
MIN | NOM | MAX | UNIT | |||
---|---|---|---|---|---|---|
POWER SUPPLY | ||||||
High-voltage analog power supplies | HV_AVDD to HV_AVSS | 10 | 36 | V | ||
HV_AVSS to AGND | –18 | 0 | ||||
HV_AVDD to AGND(1) | 5 | 36 | ||||
Low-voltage analog power supply | AVDD to AGND | 4.75 | 5 | 5.25 | V | |
Digital power supply | DVDD to DGND | 2.7 | 5.25 | V | ||
SIGNAL INPUTS | ||||||
V(AINX) | Absolute input voltage | See the PGA Operating Range section | V | |||
VIN | Differential input voltage range(2) | VIN = VAINP – VAINN | –20 | ±VREF / Gain | 20 | V |
VOLTAGE REFERENCE INPUTS | ||||||
VREF | Reference voltage input | VREF = V(REFPx) – V(REFNx) | 0.9 | AVDD | V | |
V(REFNx) | Negative reference voltage | AGND– 0.05 | V(REFPx) – 0.9 | V | ||
V(REFPx) | Positive reference voltage | V(REFNx) + 0.9 | AVDD + 0.05 | V | ||
GENERAL-PURPOSE INPUT/OUTPUTS (GPIOs) | ||||||
Input voltage | AGND | AVDD | V | |||
DIGITAL INPUTS (Other Than GPIOs) | ||||||
Input voltage | DGND | DVDD | V | |||
EXTERNAL CLOCK | ||||||
f(CLK) | Frequency | Data rate < 40000 SPS | 1 | 7.3728 | 8 | MHz |
Data rate = 40000 SPS | 1 | 10.24 | 10.75 | |||
Duty cycle | 40% | 60% | ||||
TEMPERATURE RANGE | ||||||
TA | Operating ambient temperature | –45 | 125 | °C |