SBAS790C October 2018 – June 2019 ADS125H02
PRODUCTION DATA.
Reset the ADC by taking the RESET pin low for a minimum of four fCLK cycles, and then return the pin high. After reset, the conversion starts 512 / fCLK cycles later. See Figure 5 for RESET pin timing.