SBAS815A February 2017 – June 2017 ADS114S06 , ADS114S08
PRODUCTION DATA.
The devices offer digital filter options for both filtering and decimation of the digital data stream coming from the delta-sigma modulator. The implementation of the digital filter is determined by the data rate and filter mode setting. Figure 53 shows the digital filter implementation. Choose between a third-order sinc filter (sinc3) and a low-latency filter (low-latency filter with multiple components) using the FILTER bit in the data rate register (04h).
NOTE:
LL filter = low-latency filter.Regardless of the FILTER type setting, the oversampling ratio is the same for each given data rate, meaning that the device requires a set number of modulator clocks to output a single ADC conversion data. The output data rate is selected using the DR[3:0] bits in the data rate register and is shown in Table 11.
NOMINAL DATA RATE (SPS)(1) | DATA RATE REGISTER DR[3:0] | OVERSAMPLING RATIO(2) |
---|---|---|
2.5 | 0000 | 102400 |
5 | 0001 | 51200 |
10 | 0010 | 25600 |
16.6 | 0011 | 15360 |
20 | 0100 | 12800 |
50 | 0101 | 5120 |
60 | 0110 | 4264 |
100 | 0111 | 2560 |
200 | 1000 | 1280 |
400 | 1001 | 640 |
800 | 1010 | 320 |
1000 | 1011 | 256 |
2000 | 1100 | 128 |
4000 | 1101 | 64 |