SBAS824 October 2018 ADS1235
PRODUCTION DATA.
Bypass the PGA to extend the input voltage range to the analog power supply voltages. In bypass mode, the PGA is bypassed and the analog inputs are connected directly to the precharge buffers of the modulator, thereby extending the input voltage range. Be aware of the increased input current in bypass mode. See the Electrical Characteristics for the input current specification.