SBAS876C August 2018 – June 2019 ADS9224R , ADS9234R
PRODUCTION DATA.
To enable averaging of four samples, set the EN_DATA_AVG bits in the DATA_AVG_CFG register to 11b. In this mode, the device averages four samples and provides the average of four samples as output data. The output data rate reduces by a factor of four. In this mode, the host must provide four pulses separated by a time of tCYCLE (see tCYCLE for a zone 2 transfer in the Specifications section) on the CONVST pin. The device sets the READY pin high after a time of tDRDY (see tDRDY in the Specifications section) from the fourth rising edge on the CONVST pin. After the READY pin is set high, the host can read the data by using one of the protocols for reading from the device. The host can read the data while providing the four CONVST pulses for acquiring the next four samples. The host must keep tREAD < [4 × tCYCLE]. Figure 42 provides the timing for the averaging of four samples.