SBAS891B November 2017 – September 2022 ADS7142-Q1
PRODUCTION DATA
Table 7-3 provides the acronyms for different conditions in an I2C frame.
SYMBOL | DESCRIPTION |
---|---|
S | START condition for I2C frame |
Sr | RESTART condition for I2C frame |
P | STOP condition for I2C frame |
A | ACK (low) |
N | NACK (high) |
R | Read bit (high) |
W | Write bit (low) |
OPCODE | COMMAND DESCRIPTION |
---|---|
00010000b | Single register read |
00001000b | Single register write |
00011000b | Set bit |
00100000b | Clear bit |
00110000b | Reading a continuous block of registers |
00101000b | Writing a continuous block of registers |