SBAS894A
April 2018 – October 2018
ADS112C04
PRODUCTION DATA.
1
Features
2
Applications
3
Description
Device Images
K-Type Thermocouple Measurement
4
Revision History
5
Pin Configuration and Functions
Pin Functions
6
Specifications
6.1
Absolute Maximum Ratings
6.2
ESD Ratings
6.3
Recommended Operating Conditions
6.4
Thermal Information
6.5
Electrical Characteristics
6.6
I2C Timing Requirements
6.7
I2C Switching Characteristics
6.8
Typical Characteristics
7
Parameter Measurement Information
7.1
Noise Performance
8
Detailed Description
8.1
Overview
8.2
Functional Block Diagram
8.3
Feature Description
8.3.1
Multiplexer
8.3.2
Low-Noise Programmable Gain Stage
8.3.2.1
PGA Input Voltage Requirements
8.3.2.2
Bypassing the PGA
8.3.3
Voltage Reference
8.3.4
Modulator and Internal Oscillator
8.3.5
Digital Filter
8.3.6
Conversion Times
8.3.7
Excitation Current Sources
8.3.8
Sensor Detection
8.3.9
System Monitor
8.3.10
Temperature Sensor
8.3.10.1
Converting From Temperature to Digital Codes
8.3.10.1.1
For Positive Temperatures (For Example, 50°C):
8.3.10.1.2
For Negative Temperatures (For Example, –25°C):
8.3.10.2
Converting From Digital Codes to Temperature
8.3.11
Offset Calibration
8.3.12
Conversion Data Counter
8.3.13
Data Integrity Features
8.4
Device Functional Modes
8.4.1
Power-Up and Reset
8.4.1.1
Power-On Reset
8.4.1.2
RESET Pin
8.4.1.3
Reset by Command
8.4.2
Conversion Modes
8.4.2.1
Single-Shot Conversion Mode
8.4.2.2
Continuous Conversion Mode
8.4.3
Operating Modes
8.4.3.1
Normal Mode
8.4.3.2
Turbo Mode
8.4.3.3
Power-Down Mode
8.5
Programming
8.5.1
I2C Interface
8.5.1.1
I2C Address
8.5.1.2
Serial Clock (SCL) and Serial Data (SDA)
8.5.1.3
Data Ready (DRDY)
8.5.1.4
Interface Speed
8.5.1.5
Data Transfer Protocol
8.5.1.6
I2C General Call (Software Reset)
8.5.1.7
Timeout
8.5.2
Data Format
8.5.3
Commands
8.5.3.1
Command Latching
8.5.3.2
RESET (0000 011x)
8.5.3.3
START/SYNC (0000 100x)
8.5.3.4
POWERDOWN (0000 001x)
8.5.3.5
RDATA (0001 xxxx)
8.5.3.6
RREG (0010 rrxx)
8.5.3.7
WREG (0100 rrxx dddd dddd)
8.5.4
Reading Data and Monitoring for New Conversion Results
8.5.5
Data Integrity
8.6
Register Map
8.6.1
Configuration Registers
8.6.2
Register Descriptions
8.6.2.1
Configuration Register 0 (address = 00h) [reset = 00h]
Table 19.
Configuration Register 0 Field Descriptions
8.6.2.2
Configuration Register 1 (address = 01h) [reset = 00h]
Table 20.
Configuration Register 1 Field Descriptions
8.6.2.3
Configuration Register 2 (address = 02h) [reset = 00h]
Table 22.
Configuration Register 2 Field Descriptions
8.6.2.4
Configuration Register 3 (address = 03h) [reset = 00h]
Table 23.
Configuration Register 3 Field Descriptions
9
Application and Implementation
9.1
Application Information
9.1.1
Interface Connections
9.1.2
Connecting Multiple Devices on the Same I2C Bus
9.1.3
Unused Inputs and Outputs
9.1.4
Analog Input Filtering
9.1.5
External Reference and Ratiometric Measurements
9.1.6
Establishing Proper Limits on the Absolute Input Voltage
9.1.7
Pseudo Code Example
9.2
Typical Applications
9.2.1
K-Type Thermocouple Measurement (–200°C to +1250°C)
9.2.1.1
Design Requirements
9.2.1.2
Detailed Design Procedure
9.2.1.3
Application Curves
9.2.2
3-Wire RTD Measurement (–200°C to +850°C)
9.2.2.1
Design Requirements
9.2.2.2
Detailed Design Procedure
9.2.2.2.1
Design Variations for 2-Wire and 4-Wire RTD Measurements
9.2.2.3
Application Curves
9.2.3
Resistive Bridge Measurement
9.2.3.1
Design Requirements
9.2.3.2
Detailed Design Procedure
10
Power Supply Recommendations
10.1
Power-Supply Sequencing
10.2
Power-Supply Decoupling
11
Layout
11.1
Layout Guidelines
11.2
Layout Example
12
Device and Documentation Support
12.1
Device Support
12.1.1
Third-Party Products Disclaimer
12.2
Documentation Support
12.2.1
Related Documentation
12.3
Receiving Notification of Documentation Updates
12.4
Community Resources
12.5
Trademarks
12.6
Electrostatic Discharge Caution
12.7
Glossary
13
Mechanical, Packaging, and Orderable Information
6.2
ESD Ratings
VALUE
UNIT
V
(ESD)
Electrostatic discharge
Human-body model (HBM), per ANSI/ESDA/JEDEC JS-001
(1)
±2000
V
Charged-device model (CDM), per JEDEC specification JESD22-C101
(2)
±750
(1)
JEDEC document JEP155 states that 500-V HBM allows safe manufacturing with a standard ESD control process.
(2)
JEDEC document JEP157 states that 250-V CDM allows safe manufacturing with a standard ESD control process.