SBAS895D
May 2018 – May 2022
AMC1300
PRODUCTION DATA
1
Features
2
Applications
3
Description
4
Revision History
5
Device Comparison Table
6
Pin Configuration and Functions
7
Specifications
7.1
Absolute Maximum Ratings
7.2
ESD Ratings
7.3
Recommended Operating Conditions
7.4
Thermal Information
7.5
Power Ratings
7.6
Insulation Specifications
7.7
Safety-Related Certifications
7.8
Safety Limiting Values
7.9
Electrical Characteristics
7.10
Switching Characteristics
7.11
Timing Diagram
7.12
Insulation Characteristics Curves
7.13
Typical Characteristics
8
Detailed Description
8.1
Overview
8.2
Functional Block Diagram
8.3
Feature Description
8.3.1
Analog Input
8.3.2
Isolation Channel Signal Transmission
8.3.3
Analog Output
8.4
Device Functional Modes
9
Application and Implementation
9.1
Application Information
9.2
Typical Application
9.2.1
Design Requirements
9.2.2
Detailed Design Procedure
9.2.2.1
Shunt Resistor Sizing
9.2.2.2
Input Filter Design
9.2.2.3
Differential-to-Single-Ended Output Conversion
9.2.3
Application Curves
9.3
What To Do and What Not To Do
10
Power Supply Recommendations
11
Layout
11.1
Layout Guidelines
11.2
Layout Example
12
Device and Documentation Support
12.1
Documentation Support
12.1.1
Related Documentation
12.2
Receiving Notification of Documentation Updates
12.3
Support Resources
12.4
Trademarks
12.5
Electrostatic Discharge Caution
12.6
Glossary
13
Mechanical, Packaging, and Orderable Information
7.2
ESD Ratings
VALUE
UNIT
V
(ESD)
Electrostatic discharge
Human body model (HBM), per ANSI/ESDA/JEDEC JS-001
(1)
±2000
V
Charged device model (CDM), per ANSI/ESDA/JEDEC JS-002
(2)
±1000
(1)
JEDEC document JEP155 states that 500-V HBM allows safe manufacturing with a standard ESD control process.
(2)
JEDEC document JEP157 states that 250-V CDM allows safe manufacturing with a standard ESD control process.