SBAU425 July 2024 TMCS1127
The following are instructions to set up and use the TMCS1127xEVM. Figure 2-1 shows an example of a simple, low-side setup on the A1 (25mV/A) sensitivity variant. This device has isolation, and external supplies are distinguished by "high voltage" (HV) for load and "low voltage" (LV) for DUT supply. The HV supply can be isolated and at a different potential than the LV supply.
When measuring current, verify that the equipment (wires, connectors, and more) can support the amperage and power dissipation. Then verify that the current flowing through the inputs of the device is kept within the safe operating area limits of the device found in the TMCS1127 250kHz Hall-Effect Current Sensor With Reinforced Isolation Working Voltage and Ambient Field Rejection data sheet. Failure to adhere to these limits can result in damage to the EVM, or personal injury.
Do not touch the HV terminals.
Hot surface. Contact can cause burns. Do not touch!