The following procedures are used to
configure a measurement evaluation with an electronic load.
For low-side measurements:
- Connect the electronic load positive input terminal to the
positive terminal of a supply capable of sourcing the desired amount of
maximum load current.
- Connect the electronic load
negative output terminal to the load sinking terminal of the EVM
- Connect the load sourcing
terminal of the EVM (IS+ or IS–) to the external supply GND
- Turn on all the connected supplies
- Apply load with electronic load or actual system load
- Measure the output voltage at
the OUT test point
For high-side measurements:
- Connect the electronic load
positive input terminal to the load sourcing terminal (IS+ or IS–) of the
EVM. For high-side measurement of forward current, IS– sources to the
electronic load; for reverse current, IS+ sources to the load.
- Connect the electronic load
negative output terminal to the external supply GND terminal
- Connect the external supply
to the load sinking terminal of the EVM
- Turn on all the connected
supplies
- Apply load with electronic
load or actual system load
- Measure the output voltage at
the OUT test point
Note:
Set VREF, Gain and load
current direction so that the output voltage is within the linear range between
GND and VS.