SBOK054 December   2022 LMH5485-SEP

 

  1.   1
  2.   Trademarks
  3. 1Texas Instruments Enhanced Product Qualification and Reliability Report
  4. 2Space Enhanced Plastic Production Flow
  5. 3Qualification by Similarity (Qualification Family)
  6. 4Outgas Test Report

Outgas Test Report

Outgassing test was performed on 5 units. A total mass loss (TML) of 1.00% and collected volatile condensable material (CVCM) of 0.10% were used as screening levels for rejection of spacecraft materials. The outgas test was performed in a vacuum environment of less than 5 × 10 –5 torr according to ASTM E 595, for a duration of 24 hours, at 125°C. The TML, CVCM, and the amount of Water Vapor Recovered (WVR) were measured after the test.

Table 4-1 Outgas Test Results
SAMPLE TML
(%)
CVCM
(%)
WVR
(%)
LMH5485-SEP 0.07 <0.01 0.06