SBOK082 December   2024 TRF0208-SEP

 

  1.   1
  2.   2
  3.   Trademarks
  4. 1Device Information
    1. 1.1 Product Description
    2. 1.2 Device Details
  5. 2Total Dose Test Setup
    1. 2.1 Test Overview
    2. 2.2 Test Description and Facilities
    3. 2.3 Test Setup Details
      1. 2.3.1 Unbiased
      2. 2.3.2 Biased
    4. 2.4 Test Configuration and Condition
  6. 3Total Ionizing Dose Characterization Test Results
    1. 3.1 Total Ionizing Dose RHA Characterization Summary Results
  7. 4Applicable and Reference Documents
    1. 4.1 Reference Documents
  8. 5HDR Total Ionizing Dose Report

Test Description and Facilities

The TRF0208-SEP HDR exposure was performed on biased and unbiased devices in a Co-60 gamma cell at TI CLAB facility in Dallas, Texas. The unattenuated dose rate of this cell is 50-300 rad(Si)/s. After exposure, the devices were packed in dry ice (per MIL-STD-883 Method 1019 section 3.10) and returned to TI Dallas for a full post irradiation electrical evaluation using Texas Instruments' ATE. The ATE test limits are set within VID electrical limits and are guardbanded to provide a minimum Cpk and test error margin based on initial qualification and characterization data. Post irradiation measurements were taken within 30 minutes of removal of the devices from the dry ice container. The devices were allowed to reach room temperature prior to electrical post irradiation measurements.