SBOK092 December 2024 OPA4H199-SP
The production OPA4H199-SP is rated to a total ionizing dose (TID) of 100krad(Si). In the course of the SEE testing, the heavy-ion exposures delivered approximately 10krad(Si) per 107 ions/cm2 run. The cumulative TID exposure was controlled below 100krad (Si) per unit. All six OPA4H199-SP devices used in the studies described in this report were fully-functional after the heavy-ion SEE testing was completed.