SBOS721B October 2014 – October 2024 TMP75B-Q1
PRODUCTION DATA
The TMP75B-Q1 operates as a target device only on the two-wire bus and SMBus. Connections to the bus are made using the open-drain I/O lines, SDA and SCL. The SDA and SCL pins feature integrated spike-suppression filters and Schmitt triggers to minimize the effects of input spikes and bus noise. The TMP75B-Q1 supports the transmission protocol for both fast (1kHz to 400kHz) and high-speed (1kHz to 3MHz) modes. All data bytes are transmitted MSB first.