Figure 2-2 shows an example of how to set up the EVM for single-supply operation with a
direct voltage connection to the reference pin.
Figure 2-2 Single-Supply Configuration,
Direct Reference Connection
+VS to test point TP1
GND to test point TP11
Install jumper shunt to positions 2 and 3 on
J1
Remove resistor R5 for REFA
Remove resistor R25 for
REFB
Reference voltage to test point REFA (TP10)
Reference voltage to test
point REFB (TP18)
Differential input signal connect to test points
VinA– (TP14) and VinA+ (TP17) of channel A
Differential input signal
connect to test points VinB– (TP20) and VinB+ (TP22) of channel B
Observe output at test point VOA (TP15)
Observe output at test
point VOB (TP21)
Note: C15 and C22 are
prepopulated with 0.1-µF power-supply decoupling capacitors. C22 is not required to
be removed for proper single-supply operation. See the respective device data sheet
for additional power-supply decoupling information.