Power Requirements

The four preconfigured op amp test circuits are powered by V+ (positive supply), GND (ground reference), and V- (negative supply). The triple power supply connection is required for proper biasing of the preconfigured circuits. The power connection can be accessed either through banana jack connectors or surface mount test points, both are not required.

AMP-PDK-EVM V+, V-, GND Available in Banana Jack
          Connectors or Surface Mount Test Points Figure 2-8 V+, V-, GND Available in Banana Jack Connectors or Surface Mount Test Points

The pin-to-pin partition has separate power supplies and ground. The pin-to-pin circuit is powered by V+_p2p (positive supply), GND_p2p (ground reference), and V-_p2p (negative supply). A requirement is to access the pin-to-pin power connection through the surface mount test points.

AMP-PDK-EVM V+_p2p, V-_p2p, GND_p2p Available in
          Surface Mount Connectors Figure 2-9 V+_p2p, V-_p2p, GND_p2p Available in Surface Mount Connectors