SCAS521G August 1995 – July 2024 SN54AC74 , SN54AC74-SP , SN74AC74
PRODUCTION DATA
TA = 25°C | SN54AC74 | SN74AC74 | UNIT | ||||||
---|---|---|---|---|---|---|---|---|---|
MIN | MAX | MIN | MAX | MIN | MAX | ||||
fclock | Clock frequency | 100 | 70 | 95 | MHz | ||||
tw | Pulse duration | PRE or CLR low | 5.5 | 8 | 7 | ns | |||
CLK | 5.5 | 8 | 7 | ||||||
tsu | Setup time, data before CLK↑ | Data | 4 | 5 | 4.5 | ns | |||
PRE or CLR inactive | 0 | 0.5 | 0 | ||||||
th | Hold time, data after CLK↑ | 0.5 | 0.5 | 0.5 | ns |