over operating free-air temperature range (unless otherwise
noted)(1) | | | MIN | MAX | UNIT |
---|
VCC | Supply voltage range | | –0.5 | 4.6 | V |
VI | Input voltage range(2) | | –0.5 | 4.6 | V |
VO | Voltage range
applied to any output in the high-impedance or power-off state(2) | –0.5 | 4.6 | V |
VO | Output voltage
range in the high or low state(2) | –0.5 | VCC + 0.5 | V |
IIK | Input clamp current | VI < 0 | | –50 | mA |
IOK | Output clamp current | VO < 0 | | –50 | mA |
IO | Continuous output current | | | ±20 | mA |
| Continuous current through VCC or GND | | | ±50 | mA |
TJ |
Junction
temperature |
|
|
150 |
°C |
Tstg | Storage temperature range | | –65 | 150 | °C |
(1) Operation outside the Absolute Maximum Ratings may cause permanent device
damage. Absolute maximum ratings do not imply functional operation of the device at these
or any other conditions beyond those listed under Recommended Operating Conditions.
If briefly operating outside the Recommended Operating Conditions but within the
Absolute Maximum Ratings, the device may not sustain damage, but it may not be
fully functional. Operating the device in this manner may affect device reliability,
functionality, performance, and shorten the device lifetime.
(2) The input negative-voltage and output voltage ratings may be exceeded if the input
and output current ratings are observed.