SCLK051 December   2023 TPS7H2201-SP

PRODUCTION DATA  

  1.   1
  2.   Trademarks
  3. 1Device Information
    1. 1.1 Product Description
    2. 1.2 Device Details
  4. 2Total Dose Test Setup
    1. 2.1 Test Overview
    2. 2.2 Test Description and Facilities
    3. 2.3 Test Setup Details
      1. 2.3.1 Unbiased
      2. 2.3.2 Biased
    4. 2.4 Test Configuration and Condition
  5. 3TID Characterization Test Results
    1. 3.1 TID Characterization Summary Results
    2. 3.2 TPS7H2201-QMLP Data Sheet Electrical Parameters
  6. 4Applicable and Reference Documents
    1. 4.1 Applicable Documents
    2. 4.2 Reference Documents
  7.   A Appendix: HDR TID Report Data

Test Configuration and Condition

HDR devices were stressed at 3 krad(Si), 10 krad(Si), 30 krad(Si), 50 krad (Si) and 100krad(Si) for biased and unbiased conditions.

Table 2-2 HDR Biased Device Information
Total Samples: 25
Exposure Levels
3 krad(Si)10 krad(Si)30 krad(Si)50 krad(Si)100 krad(Si)
1, 2, 3, 4, 511, 12, 13, 14, 1521, 22, 23, 24, 2531, 32, 33, 34, 3541, 42, 43, 44, 45
Table 2-3 HDR Unbiased Device Information
Total Samples: 25
Exposure Levels
3 krad(Si)10 krad(Si)30 krad(Si)50 krad(Si)100 krad(Si)
6, 7, 8, 9, 1016, 17, 18, 19, 2026, 27, 28, 29, 3036, 37, 38, 39, 4046, 47, 48, 49, 50