SCLS128H December   1982  – August 2024 SN54HC240 , SN74HC240

PRODUCTION DATA  

  1.   1
  2. Features
  3. Description
  4. Pin Configuration and Functions
  5. Specifications
    1. 4.1 Absolute Maximum Ratings
    2. 4.2 Recommended Operating Conditions
    3. 4.3 Thermal Information
    4. 4.4 Electrical Characteristics
    5. 4.5 Switching Characteristics
    6. 4.6 Switching Characteristics
    7. 4.7 Operating Characteristics
  6. Parameter Measurement Information
  7. Detailed Description
    1. 6.1 Overview
    2. 6.2 Functional Block Diagram
    3. 6.3 Device Functional Modes
  8. Application and Implementation
    1. 7.1 Power Supply Recommendations
    2. 7.2 Layout
      1. 7.2.1 Layout Guidelines
  9. Device and Documentation Support
    1. 8.1 Documentation Support
      1. 8.1.1 Related Documentation
    2. 8.2 Receiving Notification of Documentation Updates
    3. 8.3 Support Resources
    4. 8.4 Trademarks
    5. 8.5 Electrostatic Discharge Caution
    6. 8.6 Glossary
  10. Revision History
  11. 10Mechanical, Packaging, and Orderable Information

Recommended Operating Conditions

over operating free-air temperature range (unless otherwise noted)(1)
SN54HC240SN74HC240UNIT
MINNOMMAXMINNOMMAX
VCCSupply voltage256256V
VIHHigh-level input voltageVCC = 2 V1.51.5V
VCC = 4.5 V3.153.15
VCC = 6 V4.24.2
VILLow-level input voltageVCC = 2 V0.50.5V
VCC = 4.5 V1.351.35
VCC = 6 V1.81.8
VIInput voltage0VCC0VCCV
VOOutput voltage0VCC0VCCV
∆t/∆vInput transition rise and fall timeVCC = 2 V10001000ns
VCC = 4.5 V500500
VCC = 6 V400400
TAOperating free-air temperature–55125–4085°C
All unused inputs of the device must be held at VCC or GND to ensure proper device operation. Refer to the TI application report, Implications of Slow or Floating CMOS Inputs, literature number SCBA004.