SFFS277 November 2023 TMS320F280033 , TMS320F280034 , TMS320F280034-Q1 , TMS320F280036-Q1 , TMS320F280036C-Q1 , TMS320F280037 , TMS320F280037-Q1 , TMS320F280037C , TMS320F280037C-Q1 , TMS320F280038-Q1 , TMS320F280038C-Q1 , TMS320F280039 , TMS320F280039-Q1 , TMS320F280039C , TMS320F280039C-Q1
The various redundancy architectures possible for the safety instrumented systems are indicated in Table 8-1. For more information, see [9].
Diagnostic Implementation | ||
---|---|---|
1 | 1oo1 Architecture | None. |
2 | 1oo1D | Diagnostic channel is implemented using various hardware diagnostic features like Watchdog, and so forth. |
3 | 1oo1D Same figure as above. | Diagnostic channel is implemented using reciprocal comparison (uses two processing units for implementing reciprocal comparison) and other hardware diagnostic features. |
4 | 1oo2 | Two different processing units are used to implement one channel. |
5 | 2oo2 | Two different processing units are used to implement one channel. |
6 | 2oo2D | Two 1oo1D structures of #2 wired together to implement a safe channel. |
7 | 2oo2D Same figure as above. | Two 1oo1D structures of #3 wired together. |
8 | 1oo2D | Similar to 2oo2D implementation of #6 with additional control lines wired to control one set of units using the other unit |
9 | 1oo2D Same figure as above. | Similar to 2oo2D implementation of #7 with additional control lines wired to control one set of units using the other unit. |