SFFS277 November 2023 TMS320F280033 , TMS320F280034 , TMS320F280034-Q1 , TMS320F280036-Q1 , TMS320F280036C-Q1 , TMS320F280037 , TMS320F280037-Q1 , TMS320F280037C , TMS320F280037C-Q1 , TMS320F280038-Q1 , TMS320F280038C-Q1 , TMS320F280039 , TMS320F280039-Q1 , TMS320F280039C , TMS320F280039C-Q1
The missing clock detector (MCD) is a safety diagnostic that can be used to detect failure of PLL reference clock. MCD utilizes the embedded 10 MHz internal oscillator (INTOSC1). This circuit only detects complete loss of PLL reference clock and doesn’t do any detection of frequency drift. The MCD circuit is enabled by default during the power-on reset state. The diagnostic can be disabled via software.