SFFS277 November 2023 TMS320F280033 , TMS320F280034 , TMS320F280034-Q1 , TMS320F280036-Q1 , TMS320F280036C-Q1 , TMS320F280037 , TMS320F280037-Q1 , TMS320F280037C , TMS320F280037C-Q1 , TMS320F280038-Q1 , TMS320F280038C-Q1 , TMS320F280039 , TMS320F280039-Q1 , TMS320F280039C , TMS320F280039C-Q1
The high-resolution capture (HRCAP) peripheral measures the width of external pulses with a typical resolution within hundreds of picoseconds. This module includes capture channel in addition to a HW calibration block to enable continuous on-line calibration, this drastically reduces software overhead to calibrate. HRCAP input can be connected to HRPWM output using X-BAR to enable periodic testing. The HRCAP enhancement has been added to eCAP 6 and eCAP 7.
The following tests can be applied as diagnostics for this module (to provide diagnostic coverage on a specific function):