SFFS700 May 2024 TMS320F28P650DH , TMS320F28P650DK , TMS320F28P650SH , TMS320F28P650SK , TMS320F28P659DH-Q1 , TMS320F28P659DK-Q1 , TMS320F28P659SH-Q1
The Dual-Clock Comparator module can be used to validate or monitor the output frequency of the PLL (PLLRAWCLK) over defined time window. While checking for the PLL Clock frequency DCC uses a known good reference clock to compare with, which is INTOSC1, INTOSC2 or XTAL. If the PLL clock frequency deviates from the targeted frequency more than a predefined threshold, DCC will report an ERROR status flag and send an interrupt to the PIE.
Proper operation of Dual clock comparator (DCC) functionality can be checked by configuring DCC with wrong ratio between counter 0 (DCCCNTSEED0) and counter 1 (DCCCNTSEED1) to force a failure. The fail flag / interrupt can then be checked to verify the functionality of DCC.