SFFS757 February   2024 DLP4620S-Q1 , DLPC231S-Q1

 

  1.   1
  2. 1Introduction
    1.     Trademarks
  3. 2 DLP4620S-Q1 Chipset Functional Safety Capability
  4. 3Development Process for Management of Systematic Faults
    1. 3.1 TI New-Product Development Process
    2. 3.2 TI Functional Safety Development Process
  5. 4 DLP4620S-Q1 Chipset Overview
    1. 4.1 Targeted Applications
    2. 4.2 DLP4620S-Q1 Chipset Functional Safety Concept
      1. 4.2.1 Typical Hazards
      2. 4.2.2 Chipset Architecture
      3. 4.2.3 Built-In Self Tests
    3. 4.3 Functional Safety Constraints and Assumptions
  6. 5Description of Hardware Component Parts
    1. 5.1 Description of System Level Built In Self Test (BISTs)
  7. 6Management of Random Faults
    1. 6.1 Fault Reporting
      1. 6.1.1 HOST_IRQ
      2. 6.1.2 Error History
      3. 6.1.3 Fault Handling
    2. 6.2 Functional Safety Mechanism Categories
    3. 6.3 Description of Functional Safety Mechanisms
      1. 6.3.1 Video Path Protection
        1. 6.3.1.1 Video Input BISTs
        2. 6.3.1.2 Video Processing BISTs
        3. 6.3.1.3 Video Output BISTs
      2. 6.3.2 Illumination Control Protection
        1. 6.3.2.1 Communication Interface and Register Protection
        2. 6.3.2.2 LED Control Feedback Loop Protection
        3. 6.3.2.3 Data Load and Transfer Protection
        4. 6.3.2.4 Watchdogs and Clock Monitors
        5. 6.3.2.5 Voltage Monitors
  8.   A Summary of Recommended Functional Safety Mechanism Usage
  9.   B Distributed Developments
    1.     B.1 How the Functional Safety Lifecycle Applies to TI Functional Safety Products
    2.     B.2 Activities Performed by Texas Instruments
    3.     B.3 Information Provided
  10.   C Revision History

Functional Safety Constraints and Assumptions

In creating a functional Safety Element out of Context (SEooC) concept and doing the functional safety analysis, TI generates a series of assumptions on system level design, functional Safety Element out of Context (SEooC), and requirements. These assumptions (sometimes called Assumptions of Use) are listed below. Additional assumptions about the detailed implementation of safety mechanisms are separately located in Section 6.3.

The DLP4620S-Q1 Functional Safety Analysis was done under the following system assumptions:

  • [SA_1] The system integrator shall follow all requirements in the component data sheet.
  • [SA_2] The system integrator shall enable all BISTs.

During integration activities these assumptions of use and integration guidelines described for this chipset shall be considered. Use caution if one of the above functional safety assumptions on this chipset cannot be met, as some identified gaps may be unresolvable at the system level.