SFFS779 December 2024 TMS320F28P550SJ
The LIN module supports detection of no-response error detection. An error flag bit is set and an interrupt is generated when the header of the initiator does not complete a response within TFRAME_MAX (the maximum time length allowed for response). The no-response error flag is cleared by reading the corresponding interrupt offset in the SCIINTVECT0/1 register.