SFFS889 July 2024 TMS320F2800132 , TMS320F2800133 , TMS320F2800135 , TMS320F2800137
The missing clock detector (MCD) is a safety diagnostic that can be used to detect a failure of the PLL reference clock. MCD uses the embedded 10MHz internal oscillator (INTOSC1). This circuit only detects complete loss of the PLL reference clock and does not detect frequency drift. The MCD circuit is enabled by default during the power-on reset state. The diagnostic can be disabled through software.