SLAA721E October 2016 – March 2020 MSP430FR5969 , MSP430FR5969-SP , MSP430FR5994 , MSP430FR6989
MSPBoot forces a reset when the Communication Protocol detects that the download is complete and the device should jump to the application.
FRAM devices use a software BOR to force reset, which provides an efficient method to restore the MSP430 MCU to a default state. Declaration HW_RESET_BOR is enabled by default.