SLAAED9 November 2023 TAA5412-Q1 , TAC5311-Q1 , TAC5312-Q1 , TAC5411-Q1 , TAC5412-Q1
Bit | Field | Type(1) | Reset | Description |
---|---|---|---|---|
7 | INT_LIVE2 | R | 0b | Interrupt due to GPA up
threshold fault 0b = No interrupt 1b = Interrupt |
6 | INT_LIVE2 | R | 0b | Interrupt due to GPA low
threshold fault 0b = No interrupt 1b = Interrupt |
5 | INT_LIVE2 | R | 0b | Interrupt due to VAD power
up detect 0b = No interrupt 1b = Interrupt |
4 | INT_LIVE2 | R | 0b | Interrupt due to VAD power
down detect 0b = No interrupt 1b = Interrupt |
3 | INT_LIVE2 | R | 0b | Interrupt due to MICBIAS
short circuit condition 0b = No interrupt 1b = Interrupt |
2 | INT_LIVE2 | R | 0b | Interrupt due to MICBIAS
High current fault 0b = No interrupt 1b = Interrupt |
1 | INT_LIVE2 | R | 0b | Interrupt due to MICBIAS Low
current fault 0b = No interrupt 1b = Interrupt |
0 | INT_LIVE2 | R | 0b | Interrupt due to MICBIAS
Over voltage fault 0b = No interrupt 1b = Interrupt |